    HONEYWELL® 1-Input Monitor Module [TC809E1043]
    HONEYWELL® 1-Input Monitor Module
    Ref.: TC809E1043
    Provides single channel monitoring of normally open contact fire alarm and supervisory devices. The TC809E1043 has a single tri-colour green/red/yellow LED, which can be set by panel command to pulse green each time the module is polled. In case of an alarm the panel can switch the red indicator on continuously. The Yellow LED is controlled by the module and blinks to indicate an open circuit on the input circuit. This fault indication is overridden by a panel command to turn the red LED on.
    V.A.T. included
    Consult
    HONEYWELL® 1-Output Monitor Module [TC810E1032]
    HONEYWELL® 1-Output Monitor Module
    Ref.: TC810E1032
    The TC810E1032 output module allows the control of auxiliary devices such as fire shutters or sounders. A single tri-colour LED indicates the status of the module. In normal conditions, the LED can be set by command from the control panel to blink green when the module is polled. When the control panel switches the relay to the energised state the LED can be set to continuous green. In the case of an open circuit or fault on the output circuit, the module will set the LED to blink yellow.
    V.A.T. included
    Consult
    HONEYWELL® 2-Input Monitor Module [TC809E1050]
    HONEYWELL® 2-Input Monitor Module
    Ref.: TC809E1050
    Provides single channel monitoring of normally open contact fire alarm and supervisory devices. The TC809E1050 has a single tri-colour green/red/yellow LED, which can be set by panel command to pulse green each time the module is polled. In case of an alarm the panel can switch the red indicator on continuously. The Yellow LED is controlled by the module and blinks to indicate an open circuit on the input circuit. This fault indication is overridden by a panel command to turn the red LED on.
    V.A.T. included
    Consult
    HONEYWELL® Analog Optical White Detector [TC806ES1012]
    HONEYWELL® Analog Optical White Detector
    Ref.: TC806ES1012
    Analogue addressable photoelectronic sensors are plug-in type smoke sensors that combine a photoelectronic sensing chamber with addressable-analogue communications. These sensors are designed for open area protection and must only be connected to control panels that use a compatible proprietary analogue addressable communciation protocol for monitoring and control.
    V.A.T. included
    Consult
    HONEYWELL® Monitor Module [TC809EA1035]
    HONEYWELL® Monitor Module
    Ref.: TC809EA1035
    The TC809EA1035 monitor module can be installed in a single gang junction box directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting (see Figure 1). The TC809EA1035 is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary decade switches. It provides a two-wire initiating circuit for normally open contact fire alarm and security devices.
    V.A.T. included
    Consult
    HONEYWELL® OMNI Prox™ Reader (Refurbished) [GCD10F301]
    HONEYWELL® OMNI Prox™ Reader (Refurbished)
    Ref.: GCD10F301
    ProxPoint® Plus Proximity Reader (125 KHz) ideal for use indoor or outdoor. Designed to not bother the plunge and allows mounting directly on metal. Wiegand output.
    V.A.T. included
    Consult
    HONEYWELL® Relay Module with 240V Output - DIN Rail [TC810E1057]
    HONEYWELL® Relay Module with 240V Output - DIN Rail
    Ref.: TC810E1057
    The relay module is a looppowered device controlling an unsupervised double pole (one normally open, one normally closed) output suitable for managing 240V ac loads. The output relay is a bi-stable device, latching in the on or off state on command from the control panel. It is available in two versions: boxed, wall mount and 35mm ‘Top Hat’ DIN rail mount.
    V.A.T. included
    Consult
    HONEYWELL™  GALAXY™ Flex Central V3 20 Kit+ Keyboard + IP / GPRS Module - G3 [C015-E1-K11GI]
    HONEYWELL™ GALAXY™ Flex Central V3 20 Kit+ Keyboard + IP / GPRS Module - G3
    Ref.: C015-E1-K11GI
    Kit with HONEYWELL™ GALAXY™ Flex™ V3 Grade 3 control panel 20 zones. Keyboard MK-7. IP communication module + GPRS. Special box Grade 3. 393 x 367 x 98 mm.
    V.A.T. included
    Consult
    HONEYWELL™ 150 kg / 1470N Surface Electromagnet [RPS-1384]
    HONEYWELL™ 150 kg / 1470N Surface Electromagnet
    Ref.: RPS-1384
    Electromagnet for emergency doors and surface mounting of 150 Kg / 1470 N. Aluminum body and ferromagnetic plate made of galvanized steel. Requires 12VDC 300mA or 24VDC 150mA power. IP40 protection index. Dimensions A: 170 mm H: 35 mm F: 21 mm.
    V.A.T. included
    Consult
    HONEYWELL™ 2 x 500 kg / 9800N Surface Electromagnet (Double Blade)  [RPS-1395]
    HONEYWELL™ 2 x 500 kg / 9800N Surface Electromagnet (Double Blade)
    Ref.: RPS-1395
    Electromagnet for emergency doors and 2 x 500 Kg / 9800 N double sheet surface mounting. Aluminum body, galvanized steel ferromagnetic plate, LED and status indicator relay. Requires 12VDC 1A or 24VDC 500mA power. IP40 protection index. Dimensions A: 530 mm H: 140 mm F: 80 mm.
    V.A.T. included
    Consult
    HONEYWELL™ 300 kg / 2490N Door Rack Electromagnet [RPE-1385]
    HONEYWELL™ 300 kg / 2490N Door Rack Electromagnet
    Ref.: RPE-1385
    Electromagnet for emergency doors and recessed mounting in the door frame of 300 Kg / 2490 N. Aluminum body and ferromagnetic galvanized steel plate. Requires 12Vdc 500mA or 24Vdc 250mA. IP 40 protection index. Dimensions A: 230 mm H: 39 mm F: 26 mm.
    V.A.T. included
    Consult
    HONEYWELL™ 300 kg / 2490N Surface Electromagnet [RPS-1388]
    HONEYWELL™ 300 kg / 2490N Surface Electromagnet
    Ref.: RPS-1388
    Electromagnet for emergency doors and surface mounting of 300 Kg / 2490 N. Aluminum body and galvanized steel ferromagnetic plate. Requires 12 VDC 500 mA or 24 VDC 250 mA power. IP40 protection index. Dimensions A: 250 mm H: 48 mm F: 25 mm.
    V.A.T. included
    Consult
    HONEYWELL™ 400N Floor or Wall Retainer with 150mm Bracket and Fire Door Push Button [960121]
    HONEYWELL™ 400N Floor or Wall Retainer with 150mm Bracket and Fire Door Push Button
    Ref.: 960121
    400N wall retainer, with folding support at 90º (150mm) for floor or 180o (175mm) for wall. Rotating plastic fiber reinforced plastic head and red release button. The device releases the door when the 24 VDC voltage is no longer applied. Includes protection and polarization diode and articulated ferromagnetic plate Ref. 960110. Requires 24 VDC 67 mA power.
    V.A.T. included
    Consult
    HONEYWELL™ 400N Floor or Wall Retainer with 300mm Bracket and Fire Door Push Button [960122]
    HONEYWELL™ 400N Floor or Wall Retainer with 300mm Bracket and Fire Door Push Button
    Ref.: 960122
    400N wall retainer, with folding support at 90o (300mm) for floor or 180o (325mm) for wall. Rotating plastic fiber reinforced plastic head and red release button. The device releases the door when the 24VDC voltage is no longer applied. Includes protection and polarization diode and articulated ferromagnetic plate Ref. 960110. Requires 24 VDC 67 mA power.
    V.A.T. included
    Consult
    HONEYWELL™ 400N Wall Retainer with Box and Push Button for Fire Door [960120]
    HONEYWELL™ 400N Wall Retainer with Box and Push Button for Fire Door
    Ref.: 960120
    400N wall retainer with box and push button, for fire door. Plastic case reinforced with fiber and red release button. The device releases the door when the 24 VDC voltage is no longer applied. Includes protection and polarization diode and articulated ferromagnetic plate Ref. 960110. Requires 24 VDC 67mA power.
    V.A.T. included
    Consult
    HONEYWELL™ 4140XMPT2-EX Control Panel [4140XMPT2-EX]
    HONEYWELL™ 4140XMPT2-EX Control Panel
    Ref.: 4140XMPT2-EX
    The 4140XMPT2-EX intruder panel offers an extensive feature set at a remarkable competitive price. This multiplexed panel offers 9 zones, up to 86 in total taht can be wireless. Arming/disarming can be performed wireless by keyfobs. This panel even gives you the possibility to define your own zone functions. 128 user codes, and 512 events.
    V.A.T. included
    Consult
    HONEYWELL™ 4939SN-WH Magnetic Contact [4939SN-WH]
    HONEYWELL™ 4939SN-WH Magnetic Contact
    Ref.: 4939SN-WH
    V-Plex Addressable Surface Mount Contact. Programmable surface mount contact. Compatible with control panels with serial number device capabilities for multiplex polling loop. Standard gap: 1-1/4" (32mm). 5" (1.5m) CLII jacketed cable. Epoxy sealed for protection from moisture and impact. Programmed from VISTA keypad or learn mode. Switch Type: Form A (SPST) Reed. Contact Rating: 100ma @ 28VDC. Honeywell Exclusive: Patent polling loop technology.
    V.A.T. included
    Consult
    HONEYWELL™ 4944SN-WH Magnetic Contact [4944SN-WH]
    HONEYWELL™ 4944SN-WH Magnetic Contact
    Ref.: 4944SN-WH
    Flush mount magnetic contact for residential applications.
    V.A.T. included
    Consult
    HONEYWELL™ 4959SN Magnetic Contact - G2 [4959SN]
    HONEYWELL™ 4959SN Magnetic Contact - G2
    Ref.: 4959SN
    V-Plex Programmable Overhead Door Contact. Rugged aluminum housing and adjustable L bracket type magnet. Standard gap: 2" (51mm). 24" (61cm) armored cable. Epoxy sealed for protection from moisture and impact. Programmed from VISTA keypad. Switch Type: Form A (SPST) Reed. Contact Rating: 100ma @ 28VDC. Honeywell Exclusive: Patent polling loop technology
    V.A.T. included
    Consult
    HONEYWELL™ 500 kg / 4900N Surface Electromagnet - IP65 [RPS-1396]
    HONEYWELL™ 500 kg / 4900N Surface Electromagnet - IP65
    Ref.: RPS-1396
    Electromagnet for emergency doors and surface mounting 500Kg / 4900N. Stainless steel body, galvanized steel ferromagnetic plate, LED and status indicator relay. Requires 12VDC 500mA or 24VDC 250mA power. IP65 protection index for outdoor use. Dimensions A: 265 mm H: 70 mm F: 40 mm.
    V.A.T. included
    Consult
    HONEYWELL™ 500 kg / 4900N Surface Electromagnet [RPS-1392]
    HONEYWELL™ 500 kg / 4900N Surface Electromagnet
    Ref.: RPS-1392
    Electromagnet for emergency doors and surface mounting of 500 Kg / 4900 N. Aluminum body, galvanized steel ferromagnetic plate, LED and status indicator relay. Requires 12VDC 500mA or 24VDC 250mA power. IP40 protection index. Dimensions A: 265 mm H: 70 mm F: 40 mm.
    V.A.T. included
    Consult
    HONEYWELL™ 50kg Electromagnet in Box with Push Button. [13150-24D]
    HONEYWELL™ 50kg Electromagnet in Box with Push Button.
    Ref.: 13150-24D
    Electromagnetic device for retention of fire doors, with metal box and release button. Cream. Connection by strip. Protected electrical circuit with capacitor and diodes. Provided with ferromagnetic ball joint. Power: 24Vdc. Consumption: 45mA. Force: 50Kg / 445Nw. Protection degree: IP40. CPD Certificate: 0407-CPD-065.
    V.A.T. included
    Consult
    HONEYWELL™ 850N Wall Retainer with Box and Push Button for Fire Door [960119]
    HONEYWELL™ 850N Wall Retainer with Box and Push Button for Fire Door
    Ref.: 960119
    850N wall retainer with box and push button, for fire door. Plastic case reinforced with fiber and red release button. The device releases the door when the 24 VDC voltage is no longer applied. Includes protection and polarization diode and articulated ferromagnetic plate Ref. 960114. Requires 24 VDC 92 mA power.